Insulation plates are typically used to break the electrical contact between dissimilar metals (e.g. fastening a stainless steel cleat onto a galvanised structure) and mitigate the risks of bi-metallic corrosion . Ellis offers a range of insulation plates to suit different cleat sizes. The plates are manufactured as standard in black polypropylene or black flame retardant VO zero halogen UV stabilised nylon (LSF).
Swipe/scroll right for more
Part No. | Material Suffix | Pack Qty | Weight g |
---|---|---|---|
91-IP | B | 100 | 5 |
91-IP12 | B/LSF | 100 | 5 |
91-IP-1 | B/LSF | 100 | 5 |
91-IP-2 | B/LSF | 100 | 5 |
91-IP-3 | B/LSF | 100 | 5 |
Typical Cleat recommendations are as follows:
Emperor
91-1P-1: ER19-23 to ER33-38 and ES32-39 to ES65-73
91-IP-2: ER36-42 to ER51-58 and ES73-85 to ES94-118
91-IP-3: ER55-62 to ER119-128 and ES118-130 to ES127-150
Vulcan+
91-IP: VRT+00 to VRT+02 and VRQ+01 to VRQ+02
91-IP-1: VRT+03 to VRT+06 and VRQ+03 to VRQ+04
91-IP-2: VRT+07 to VRT+12 and VRQ+05 to VRQ+08
91-IP-3:VRT+13 to VRT+20 and VRQ+09